MIAMI -- EMCOR Group Inc. announced that its Poole & Kent Co. of Florida subsidiary has been awarded a mechanical construction contract by the University of Miami School of Medicine campus in Miami.

Poole & Kent will install a piping system that will provide 17,000 tons of chilled water to various buildings on the University’s School of Medicine campus. The project will involve 7,200-ft. of up to 36-in. underground, insulated piping, as well as all system valves and fittings. The scope of work will include pipe identification and markers; cleaning and flushing of the new pipe system; all excavation, backfill and pipe bleeding; cold patching, road plates and sidewalk concrete; roadway restoration, paving and curbs; milling resurfacing of asphalt; storm sewer protection and pavement marking; concrete topping of CHW lines; and additional work for the chiller plant connection.

“Poole & Kent has been working with the University of Miami for over 30 years and we’re excited to continue that relationship through this important project -- a chilled water distribution system that will provide added capacity to the Medical School for expansion and energy conservation,” said Steven C. Jordan, president and CEO of Poole & Kent Co. of Florida.

Want to use this article? Click here for options!
© 2008 Penton Media Inc.

This Month's Products

Products

THIS AUTOMATED BACK-UP POWER SOURCE

couples with any HVAC unit or boiler to provide a continual supply of power so long as fuel supply (natural gas, propane or oil) is uninterrupted.

Everlite Hybrid Industries


Products

THE N-0751M-DVC CONCENTRIC VENTING HEATER

is an indoor-only tankless unit that delivers up to 9.8 GPM of hot water. It is easy to install with zero venting clearance. It uses the same heat exchanger found in the company's high-end commercial units.


Products

THE GT SERIES OF HORIZONTAL SPLIT-CASE PUMPS

includes six models with flow capacities between 5,800 to 17,500 GPM with heads up to 360'. The pumps have a standard operating pressure of 175 psig and can handle fluid temperatures up to 250°F (120°C).

Products

THIS HOSE BIBB LOCK

is designed to protect any standard ¾" outdoor faucet or hose spigot. As drought conditions have plagued dozens of states, water theft has become considerably more common.

Contractor Opinion Poll

Industry Resources

  • November 2008 cover
  • October 2008 cover
  • September 2008 cover
  • Aug 2008 cover
  • July 2008 cover
  • June 2008 cover
  • May 2008 cover

Browse Back Issues